Welcome to the Peterson Real Fyre G10-24/30 manual, your comprehensive guide to installing, operating, and maintaining this vent-free gas burner system. Ensure safety and optimal performance by following the detailed instructions and recommendations provided.

Overview of the G10-24/30 Burner System

The G10-24/30 burner system, part of the Peterson Real Fyre series, is a vent-free gas burner designed for use with compatible 24″ and 30″ log sets. It operates on natural gas or propane and features a manual control system. With a BTU rating range of 19,000 to 36,000, it offers efficient heat output. This system is ANSI certified, ensuring safety and compliance with industry standards. It is engineered for seamless integration with specific Real Fyre log sets, providing a realistic flame pattern and reliable performance.

Key Features and Specifications

The Peterson Real Fyre G10-24/30 is a vent-free burner system compatible with 24″ and 30″ log sets, operating on natural gas or propane with a 19,000–36,000 BTU range. ANSI certified, it features manual controls and is designed for energy efficiency.

BTU Rating and Fuel Type

The Peterson Real Fyre G10-24/30 burner system offers a BTU rating range of 19,000 to 36,000 BTU/Hr, providing flexible heating options. It is compatible with both natural gas (NG) and propane (LP), ensuring versatility for different fuel sources. This range allows the system to efficiently heat various-sized spaces while maintaining energy efficiency. Proper fuel selection and installation are crucial for optimal performance and safety, as outlined in the manual.

Vent-Free Design and Efficiency

The Peterson Real Fyre G10-24/30 features a vent-free design, utilizing room air for combustion and eliminating the need for external venting. This system boasts a 99% heating efficiency, operating with minimal gas consumption. ANSI certified, it ensures safe and reliable performance. The vent-free technology allows for straightforward installation and maintenance, making it an energy-efficient choice for heating spaces without compromising on safety or convenience.

Installation Instructions

Follow the G10-24/30 manual for proper installation, ensuring compliance with safety standards and location requirements. Correct log placement and burner alignment are crucial for optimal performance and safety.

Preparation and Safety Precautions

Before installing the G10-24/30 burner, ensure the area is clear of flammable materials and proper ventilation is available. Always adhere to local building codes and safety standards. Inspect the gas supply line for leaks and ensure it meets the system’s specifications. Turn off the gas supply during installation. Never attempt to modify the burner or logs, as this can lead to safety hazards. Consult a qualified technician if unsure about any step to ensure compliance and safety.

Step-by-Step Installation Guide

Locate the burner in the fireplace, ensuring proper alignment with the gas connection. 2. Attach the burner to the approved log set, securing it firmly. 3. Connect the gas line to the burner, ensuring a leak-tight seal. 4. Install the decorative lava rock or embers around the burner for a realistic appearance. 5. Test the ignition system to confirm proper operation. 6. Ensure all connections are secure and the system is ready for use.

Log Placement and Alignment

Proper log placement is crucial for both safety and aesthetic appeal. Position the logs securely on the burner, ensuring they do not obstruct gas ports. Use only approved log sets specifically designed for the G10-24/30 burner. Arrange the logs to mimic a natural fire, with larger pieces toward the rear and smaller ones in front. Use decorative lava rock or embers around the burner for a realistic appearance. Ensure all logs are stable and properly aligned to maintain even combustion and safety.

Safety Guidelines and Precautions

Ensure proper ventilation and maintain clearances from combustible materials. Never use unapproved log sets or parts. Keep the area around the burner free from flammable materials to prevent hazards.

Proper Ventilation Requirements

Ensure adequate ventilation for proper combustion and safety. The G10-24/30 burner uses room air for combustion, so maintain sufficient airflow; Calculate room volume to confirm it meets ventilation standards. Avoid installing in tightly sealed spaces without proper air exchange. Keep windows or doors slightly open if necessary. Improper ventilation can lead to carbon monoxide buildup. Always follow manual guidelines for ventilation to ensure safe operation and comply with local building codes.

Clearance and Installation Location

The G10-24/30 burner requires specific clearances to ensure safe operation. Maintain minimum distances from combustible materials, such as walls and furniture. Install the burner on a stable, heat-resistant surface. Ensure the area around the burner is clear of flammable items. Follow the manual’s guidelines for proper placement to avoid hazards. Always verify local building codes for additional requirements. Proper installation location and clearance are critical for safety and performance.

Maintenance and Upkeep

Regular servicing ensures optimal performance and safety. Clean the burner and logs as instructed, and inspect for wear. Use only authorized parts for replacements;

Cleaning and Inspection Procedures

Regular cleaning ensures efficient operation and safety. Turn off the gas supply and let the burner cool. Use a soft brush or vacuum to remove dust and debris from the logs and burner. Inspect burner ports for obstructions and clean as needed. Check for any signs of wear or damage on the logs and controls. Replace any damaged parts with authorized Peterson Real Fyre components. Proper maintenance extends the lifespan of your system and ensures optimal performance.

Recommended Maintenance Schedule

Perform daily checks to ensure the burner and logs are free from debris. Monthly, inspect gas lines for leaks and burner ports for blockages. Annually, hire a certified technician to inspect the system and replace worn parts. Replace logs every 5-7 years or as needed. Follow the manufacturer’s schedule to maintain efficiency, safety, and warranty compliance. Regular upkeep prevents issues and ensures years of reliable performance from your Peterson Real Fyre G10-24/30 system.

Troubleshooting Common Issues

Identify common issues like ignition problems or uneven flames. Refer to the manual for diagnostic steps and solutions to ensure safe and effective resolution of these problems.

Diagnosing Burner Problems

Diagnose burner issues by checking ignition, flame quality, and gas flow. Ensure proper ventilation and log placement. Consult the manual for specific error symptoms and corrective actions. Verify fuel supply settings and burner cleanliness. Address clogged ports or faulty valves promptly. If issues persist, contact authorized Peterson Real Fyre support for professional assistance. Always follow safety guidelines during troubleshooting to avoid hazards.

Resolving Common Operational Issues

Address operational issues by first identifying symptoms like inconsistent flames or ignition failure. Check the fuel supply and ensure proper gas flow. Clean burner ports regularly to prevent blockages. Verify log placement aligns with manual instructions for optimal performance. Adjust the burner settings as needed to achieve a steady, even flame. If issues persist, consult the troubleshooting section or contact Peterson Real Fyre support for assistance. Always prioritize safety when resolving operational problems.

Compatibility with Log Sets

The G10-24/30 burner is designed for use with specific Peterson Real Fyre Charred Series Log Sets, ensuring optimal performance and safety. Always use approved log sets.

Approved Log Sets for G10-24/30

The G10-24/30 burner is specifically designed to work with Peterson Real Fyre’s 24-inch and 30-inch Charred Series Log Sets. These log sets are engineered to ensure proper combustion, safety, and aesthetic appeal. Using approved log sets is crucial for maintaining efficiency and meeting safety standards. Always verify compatibility with the burner system before installation. For detailed specifications, consult the manual or contact Peterson Real Fyre support.

Ensuring Proper Compatibility

Proper compatibility between the G10-24/30 burner and log sets is essential for optimal performance and safety. Always use Peterson Real Fyre-approved log sets designed for this burner. Verify the size and type of logs match the burner specifications. Incorrect log placement may affect combustion efficiency and safety. Refer to the manual for a list of compatible log sets and installation guidelines. Adherence ensures compliance with safety standards and maximizes the system’s efficiency and visual appeal.

The Peterson Real Fyre G10-24/30 manual provides essential guidance for safe and efficient installation, operation, and maintenance. Follow instructions carefully for optimal performance and longevity.

Final Tips for Optimal Performance

For the best experience with your Peterson Real Fyre G10-24/30 burner, ensure proper log placement and alignment as specified in the manual. Regularly inspect and clean the burner to maintain efficiency; Always use approved log sets and genuine parts for safety and performance. Schedule annual professional inspections to comply with safety standards; Keep the surrounding area clear of flammable materials and ensure proper ventilation in the room. Follow the recommended maintenance schedule to extend the lifespan of your system.

Additional Resources

For further assistance, visit the official Peterson Real Fyre website for the complete G10-24/30 manual, troubleshooting guides, and customer support contact information.

Where to Find the Full Manual and Support

The complete Peterson Real Fyre G10-24/30 manual is available for download on the official RH Peterson website. Visit their support section for detailed installation guides, troubleshooting tips, and ANSI-certified specifications. For additional assistance, contact their customer support team via phone or email. Authorized dealers also provide hands-on help and genuine parts for optimal performance.